hp msa1000 end of life. Data Availability, Protection and Retention. hp msa1000 end of life

 
 Data Availability, Protection and Retentionhp msa1000 end of life Solved

Any help. I would prefer "disable this_controller", cause. When creating a 6x72gb Raid 5 set, the "Parity Init" is taking 5 hours ! Surely this cannot be right. In this i have oracle datafiles. Version History: Download PDF. Have an HP MSA 1000 and need to upgrade the firmware on it. I use FCA2214 2G HBA card connect. . MSA1000 Config:-- 4 hosts connected to HP 4/10q fiber switch via one HBA-- MSA1000 connected to the switch via the fiber I/O module-- Single controller setup-- 13 disk array with 1 spare-- Six 400 GB luns configured as RAID5The last MSA1000 support CD is dated Feb 2007. If connections between the HBAs and the. It gives you the combination of simplicity, flexibility, and advanced features you may not expect in an entry-priced array. As always, the MSA1000 comes complete with configuration and In your case, you have an MSA1000 and are limited to 14 disks. DESCRIPTION. . 3. 96 SFF or 48 LFF Maximum including expansion, depending on model. HP Master ASE, Storage, Servers, and Clustering MCSE (NT 4. based on the host's OS AND the MSA firmware version. like hp and brocade switches connecting to msa1000 storage array. Array 1000 (MSA1000), the Modular Smart Array 500 (MSA500), and the Modular Smart Array 30 (MSA30). En este capítulo se tratan los. . Hello, We lost power (I think) to one or both of our controllers in an active/standby setup on an MSA1000. Procurri makes it easy to find the latest End of Service Life (EOSL) dates for your HPE hardware. Hello, Is HP planning to support MSA1000 active/active configurations in the near future? MSA1500 active/active configs are supported with the right firmware. Hi all, I have an Alphaservers cluster running OpenVMS 7. Rev. This is the reason why your servers cannot discover the MSA1000-controller in ACU. It gives you the combination of simplicity, flexibility, and advanced features you may not expect in an entry-priced array. The HPE MSA 2040 End of Life has passed, and it’s time to start thinking about a continuity plan before the HPE MSA 2040 EOSL hits on April 30th, 2023. Es posible adquirir por separado un Controlador adicional redundante. There. I can see the disks connected via H. ESX and HP MSA1000 Hi, I am confused about how to properly configure MSA1000 with ESX 3. Request Updated Price Part Code. Solutions Hybrid IT with Cloud ; Mobile & IoT; IT for Data & Analytics; Public Sector; Service Providers; Small & Midsize Business; Financial; Health & Life Sciences; Manufacturing; Telecommunications; Media &. Otherwise resetting the MSA1000 is performed physically in front of the system. 16GB RAM and SAN HBA) - Redundant Brocade C-Class SAN Switch SAN infrastructure: - MSA1000 (2 Controllers and SCSI I/O) - 2 SAN Switches - 5 300GB SCSI 15K On one blade server we are going to run 20 VM's. DESCRIPTION. We have 8 HP StorageWorks MSA 1000 manuals available for free PDF download: Reference Manual, Installation Manual, Software Manual, Quickspecs, Hardware. And now they want to expand the MSA1000 by adding a new enclosure. The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1" universal disk. I am using this setup for testing purposes. Hi All We have a HP MSA1000 linked up to several servers via SAN Switches. Hi Guys, Can anyone of you help, I have a MSA1000 attach to a rp7400 and a N4000. I did a search on Google and found good threads in this community but it left me confused. For the interconnect options, we will purchase 2 x Gbe2c Ethernet Switch & 2 x HP Brocade SAN 4/12 Switch for reducdant propose. 7TB array. As always, the MSA1000 comes complete with configuration. 1 MSA1000 with one controller and 1 FC switch controller with type HUB 2/3 And I connected each server to this MSA1000 Can I configured these server and 1 MSA 1000 as cluster configuration using MC/SG ?. Maybe you need HP to reset the passwort. I try to use command line interface to configure the connection and raid but fail. 5 Hosts - DL380 G4 HP Blade c3000 with two blades and two Brocade 4/12 SAN Switch for HP c-Class BladeSystem Recently, I had an HP MSA1000 Fiber Channel switch replaced. It includes the MSA1000 itself along with the unique MSA SAN Switch 2/8 embedded option, two of the FCA2214 Host Bus Adapters for Windows, NetWare or Linux servers, SFPs and cabling. . 10b1200 (SGM0734AL0) Build Time: 2008-06-04 08:37:52 MSA1000 Hardware Revision:. Has anyone got any id. This manual is available in the following languages: English. I'd give a reseat of the MSA1000-switches a shot, maybe that helps. sde 0,0,0,21 COMPAQ MSA1000 VOLUME 4. On the san we are storing our SQL DB files files for SQL 2000 running on Win 2003 ent on. The servers are DL580 G1s. IT Financing and Investment Services. Hybrid IT with Cloud ; Mobile & IoT; IT for Data & Analytics; Public Sector; Service Providers; Small & Midsize BusinessI have two rx1610 servers which run hpux 11. We had a power outage which caused the SAN to power off. . I have successfully connected a test server (of the same configuration) to the MSA1000 with a Qlogic HBA, but in production I am not. Explore our database of over 20,000 parts & never miss a critical date again. Following by End of Support - no software maintenance or support services offered. Could someone possibly point me in the right direction as I am find it very difficult to source this part. and End User License Agreement. This notice is provided to help you understand the various stages of the EOL process and impacts on ordering, product availability and other important dates. The HPE MSA 2062 gives you the combination of simplicity, flexibility and advanced features you may not expect in an entry-priced storage array. To do that, I had to upgrade the firmware of the fiber controllers of our HP MSA1000 from the version 4. Get the right storage, just when you need it. Step 4: Rack the MSA1500 cs and the storage enclosures. Otherwise you may consider HP EVA with Continous Access feature for storage-based remote replication (or another vandor products from mid to high-end range). 5 Inch SFF SAS 25 Drive Enclosure (AJ840A)Hi one of the power supplies in our MSA1000 has failed and I am trying to source a new one. I have been having an interesting problem with our MSA1000. When I try to find the 4. Hello, I had to replace one of the power cables of a StorageWorks and now the MSA1000 fault LED is on, even if the redundant power has been restored. HP-UX 11. 48 600805f3000ac5c0-457669a4f4ab0048 I created six volumes on MSA1000 with unit numbers 16-21. Further details can be found in the HP StorageWorks Modular Smart Array 1000/1500cs Command Line Interface manual (just in case, like me, you found this. I have installed many of these in environment of upto 4 nodes and can state that performance was acceptable to the end client. After the EOSL date, it will not be possible to get support from HP regarding the following areas:Configuring HP StorageWorks MSA2000 storage systems. · Hi, I have actualy an HP. Installing the HPE Storeeasy 1000 Storage Hardware. The M575 has already been replaced by the M577 and now the M578. DESCRIPTION. I saw on HP's web site that a 4. Hi, What components are required on the HPSIM to monitor MSA1000? Thanks, Ana. 33TB) "GLaDOS" MSA Fabric Switch 6 (gadzoox), which is now "unsupported" as far as I know . Capacity. ioscan recognize the new volume, pvcreate ok, but i want to create vg, i got the following message. hi- i have a MSA-1000 connected to my HP Rx2620 server via FC cable . HP-SIM reports hardware fault conditions (both failure and pre-failure) and collects. I do not, however, see exactly what this firwmare does for me. . Hello All, I am trying to update the disk firmware on my MSA1000 from 8. Microsoft Windows Server 2003. If an issue is resolved on the currently Supported version of the software, customers will be encouraged to upgrade to the version that. The SAN storage subsystem will have redundant features (i. Never miss another End of Service Life announcement Get the latest EOSL information directly to your inbox Upcoming HPE EOSL Dates Model EOSL Date; D2700 Disk Enclosure : 12 / 01 / 2023 : Simplivity 380 Gen 9 Nodes : 12 / 31 / 2023. Dell PowerEdge R720 Server 2X E5. Hello, We've got the following MSA1000 setup : - 1 x MSA1000 (single controller) - 2 x MSA30 Attached Enclosures - 1 x HP 2/16-EL Fibre Switch - 8 servers (5 Windows3 VMWare) with 1 HP Branded (Emulex) HBA installed in each In order to provide better performance edundancy, we thought we'd buy t. HP Best Practices guide says to use latest firmaware but minimum of 4. i understand to use the u320 module we have to upgrade our firmware on the msa. I have added the MSA30 to my Dual Path MSA1000, and powered it up, but only drives 8-14 on bay 3 are identified by the MSA1000 controller, and therefore the ACU. 3. . I am accessing storage from HP ACU CLI/ Installed at same UNIX server (HP-UX 11. Modular Smart Array 1000 (MSA1000) Command Line Interface First Edition (September 2003) Part Number: 347282-001. One single server (DL380G2) connected directly to MSA1000 via 2 FC card in each MSA controller Server is running 2003. I was used the up-to-date firmware on HP MSA, but the SMTP server field can not resolve DNS names, because the network configuration not contain DNS server access. Part number: 257547–003 Third edition: October 2006. Skip to Footer. Simple to deploy stacking also allows up to 7 additional expansion drive enclosures to be added, increasing capacity up to 960TB. HPUX 11. My shared storage is an MSA1000 running firmware V4. HP-UX 11. I have only one pair of fiber from my system (has only one FC port) to SAN switch and one pair of Fiber from SAN switch to MSA. Periodically, windows is no longer able to see the spanned volume, and the server has to be restarted,. Steven The HPE Networking end of sale page provides a way for customers to quickly navigate to legacy products or products that have recently gone end of sale. Reference Guide HP StorageWorks 1000 Modular Smart Array Second Edition (July 2006) Part Number: 347280-002 The HP StorageWorks 1000 Modular Smart Array (MSA1000) is a 2-Gb Fibre Channel storage system designed for the entry-level to mid-range Storage Area Network (SAN). Hi - I have an MSA1000 - but it isn't in a cluster - it is just attached to two machines. after 1 meeting with reseller they just talked about some crazy crazy pricing and tried to sell new hardware. however do note that the MSA1000 is end of life. Intergrated switch reset password from the expert community at Experts Exchange. Should I still install the HBA drivers from that? I read in the HP Docs that installing from the CD sets some configuration parameters specifically for the MSA1000 which I'd have to figure out manually if I download drivers from Qlogic. . Device should be “HP MSA 2040 SAS” (6 spaces between HP and MSA) {MSA 2040 was released before HP / HPE split} You can connect cable now if all above is ok. Quorum disks on the HP MSA The FlashSystem V9000 cannot use logical units (LUs) that are exported by the HP. Can I mirror disks across the two enclosures? 2. What is the maximum number of luns that I can make on this storage. Have an HP MSA 1000 and need to upgrade the firmware on it. HP has announced the end-of-service-life for the following products. I can setup the cluster OK, and move disks from one node to the other. That looks like the MSA1000 firmware version. HP P2000 G3 FC MSA Dual Controller Virtualization SAN Starter Kit AP848B Re: MSA1000 to MSA1000 replication As far as I know HP does not provide any kind of SAN-based replication on their low end arrays, and the MSA1000 is the lowest point of the low end. Controller display with status indicators (2) and push buttons (4) on front of controller. The problem occurs when I cold boot or reboot one of. as i m. I'm getting transfer speeds in the 40-80MB/s. Can I remove the. What is the proper way to initiate a failover to the standby controller? TIA for any help. Page 5: Chapter 3: Array Configuration UtilityI'm having performance issues and am trying to determine what the bottleneck could be in my environment. 10/31/2022. Topic Options. HP ELITEDESK 800 G3. I need to extend a 200go Raid5 volume. I have built 3 LUNs with an RAID 5 array on each LUN. Modular Smart Array 1000 (MSA1000) Command Line Interface First Edition (September 2003) Part Number: 347282-001. HP customer has a dual-controller MSA1000 running firmware 5. . Does HP have any guide? Our MSA1000 is running more than eight years and basically it work fine. Buying Pre-owned extends a product's life, reducing e-waste and raw material extraction. This is the same PS/Fan assembly that is used in the EMA style HSG's and the EVA's. 33TB) "GLaDOS" MSA Fabric Switch 6 (gadzoox), which is now "unsupported" as far as I know . . The fibre connections on the MSA are attached to the server has well but they do not appear in ioscan. The "Old" : 5. However, we still have an orange (orange reddish) light on (front panel) and the message "65. HP Master ASE, Storage, Servers, and Clustering MCSE (NT 4. This process has multiple stages, which are described below. With the MSA1500cs they fixed this p. Unfortunately a lot of that P2000 firmware is locked down by HP (or HPE or HPEnterprise, whatever they call themselves now), unless you have a valid support contract with them covering the unit in question. 48). Proliant DL380 G2. 48 and "Active/Passive set to MRU" . . Those drives are assigned to a MS W3K cluster and its working fine. . Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. Fourteen 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (MSA1000 cabinet); expandable to 42 using two additional HP StorageWorks. All G3Re: MSA1000 to MSA1000 replication As far as I know HP does not provide any kind of SAN-based replication on their low end arrays, and the MSA1000 is the lowest point of the low end. I have two 8 port fibre switches with an ISL. Solved: MSA1000 - Active/Active or Active/Passive - Hewlett Packard Enterprise Community Solved: Hello, In the first quarter of this year I put into place a 4. HP needs to engage Brocade who generates a single-use recovery firmware that can be used to reset the passwords to the factory default. MSA1000. You will need to use SSP to 'assign' Luns or logical. For my other systems I was easily able to locate a part number for my 6402 Smart Array cache batteries, but I cannot find the part number for the MSA1000 Cache Batteries. Campus and Branch Networking. May 19, 2010 at 16:50. Hy there! With FW Version 4. (if applicable) repaired to excellent functional standards. OS is RedHat EL 3. But when i directly connects MSA 1000 to Server (HP-DL 380) it works to access storage. DESCRIPTION. HP StorageWorks Modular Smart Array 1000 ( MSA1000 ) 是一个 2 Gb 光纤通道存储系统。. The HPE MSA 2060 Storage is a flash-ready hybrid storage system designed to deliver hands-free, affordable application acceleration for small and remote office deployments. This notice is provided to help you understand the various stages of the EOL process and impacts on ordering, product availability and other important dates. Quote from "HP StorageWorks 1000/1500 Modular Smart Array application note Migrating to ative/active controllers in Windows environments": MSA10. Elitedesk 800 G1 could have 6/7 years, so it should be not supported (EOS) anymore by Post-Sales support. Hello possibly this has been answered in the past, but i cannot find a clear answer anywhere, I am newbie with SAN architecture and trying to learn things. e. 1. e. The Small Business SAN G2 Kit comes complete with configuration and management tools, mounting rails for Rack Only Configurations, all at no extra charge. HP 411041-001 MSA1000 redundant controller 218231-B21. I will be looking to set Secure Path up for failover to a 2nd switch should our primary switch fail and the disks have been configure with RAID 5 in the SCSI disk array should one of them. x) RHCE. . When I did mine last time I didn't pull any of them out. With the introduction of the new third generation HP StoreVirtual range in December 2012 HP is announcing the End Of Life (EOL) of the P4300 and P4500 G2 SAS nodes. I have a HP MSA 1000 disk array with 9 x 146GB SCSi drives configured as a single LUN using RAID 5. 1. . configuring an MSA1000 from scratch . i am very new to SAN and i want to know how to shutdown the MSA1000. My configuration: MSA1000. This policy helps to manage product end of life transitions and defines the role that Poly supports throughout the process. 5, as long as the. HP MSA1000 Disk Storage Enclosure. Our [partially] retired MSA has one shelf of 14 x 146GB configured as a single 1. And the 3 server is a not a cluster and is runnin. 11 U 9000/800 431264013 unlimited-user license Connected to a 4/8 SAN switch, which is connected to a MSA 1000. At the sort of density you are talking about the MSA1000 is a perfectly reasonable workhorse. Showing of 14. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. I added the MSA1000 and ,although there is traffic and the port World Wide Name is seen by the Fibre Switch, it does not get added to the Name Server Table. May 19, 2010 at 16:50. Hello. hp StorageWorks modular SAN array 1000 Support Software CD Version 6. When this is plugged back in the MSA will compare the two F/W's and prompt to ROM Clone to the older controller. Some of the encloseurs have spanned volumes over differnt arrays/enclourer swhich windows is able to see. Each MSA controller has a 2/8 SA. New HDD bundles consisting of six individual drives of either 7. Server is running HPUX 11i and has two hba cards that attached and it sees them in ioscan. Hi Folks - I know a number of you out there use the HP MSA1000 in some capacity, so I figured I'd pass along the word that the Active/Active firmware Blogs PodcastsHi all, I have added in mine msa1000 ten 145Gb 10k rpm disk drive, and I have created one new logical unit of approximately 1,2 Tb. User interface. - MSA1000 (FW V. we started talking HP and they introduced one reseller to extend warranty. Allowing you to extend. HPE Carepacks far beyond the End of Life period. I have read that is necesary a 256MB module or great in order to do this migration. I can see all of LUN in RA4100 from ACU but can'. We checked already Firmware revisions, Cable connectivity, In the logfile of the MSA1000 the battery status confuses me a bit. Page 35 Installation Procedures - for all MSA1000 Deployments 3. I am connected via Fiber Channel. Couple of questions: 1. 48 600805f3000ac5c0-14e6769fd0210047 sdf 0,0,0,22 COMPAQ MSA1000 VOLUME 4. Now i am going to implement backup solution, based on DL380 G5 server, MSL4048 Ultrium 960 Library and OpenView DataProtector. (Slot 1 is located on the front right of the HP StorageWorks MSA1000. There are 8X300G hard drives with raid1+0. SOLVED Go to solution. 10/31/2022. The only thing I have found so far is what I think is the power supply's product number 377815-001 but this doesnt provide any real help. HPE MSA 1050 SAN Storage Specifications. Now I 've connected the SAN via an other fiber to a second fileserver; On this new fileserver I'm able to see the arrays and logical drives via the ACU webtool, but can't access these drives by the window. Cabling HPE Storeeasy 1000 Storage. Once connected, it may be necessary to press the Enter key until the CLI> prompt is displayed, after which commands can be issued to configure the MSA. The MSA-1000 is a high performance, medium power silicon bipolar Monolithic Microwave Integrated Circuit (MMIC) chip. Manuals and User Guides for HP StorageWorks MSA 1000. . In this guide, you will find recommended HP training courses, reference. We have several logical drives assigned on the MSA but I cannot seem to delete any of them (except for the last one). The HPE MSA Mainstream Endurance (ME) Solid State Drive (SSD) product family is scheduled to begin its End of Life (EOL) process on 31 July 2017. I can get for a very low price used 2x MSA1000 (one with 2 controller, one with 1 controller) (6 years old) from my da. Depending upon what you are running on your ESX servers, you should look into some of the newer technologies, rather than investing in EoL hardware. 23. DESCRIPTION. Close. x. I have a MSA1000 with 2 enclosures full of 72gb 10k drives (28 drives ultra320) fibre channel is active/passive, there are 2 7port fc switches in the back of the enclosure and the only server attached (dl360 g5 windows 2003 x64) has a hba 2 port emulex. After installing Windows 2k Advanced server, we installed the needed drivers for the the fiber controller of the MSA driver software. . I have also install HP MPIO Basic Failover for MSA 10. A costly equipment upgrade might not be realistic for your shrinking IT budget, but did you know that third party data center. If backgrou. On the RP server I have a fc card part no A6795A, The MSA is link up to the rp and n-class via 2GB fibre . I have a need to replace a server (DL380) that is currently connected to the SAN wit. Now I need to reconfigure the MSA1000 with new arrays but I. end transmission speed to drives and JBODs. 00 which set the controllers in ACTIVE/ACTIVE mode. But I am afrai. Use this document to troubleshoot and maintain Hewlett Packard Enterprise MSA Storage. Close. 12) 147GB (RAID ADG, 1. . I currently am running an MSA1000 with a single controller and one external Brocade switch. Page 37 Installation Procedures - for all MSA1000 Deployments 2. Step 7: Install the HBA in the servers. After the EOSL date, it will not be possible to get support from HP regarding the following areas: Advancements to the HPE MSA Gen 6 Architecture Updates to HPE MSA deliver benefits that help to meet the needs of SMBs, including automatic tiering for faster data access, an improved MSA Health Check tool that eliminates common causes of downtime, and integration with HPE Cloud Volumes Backup for cloud backup and data archival. All 3 work fine. The Switch and FTP server. Park Place Technologies makes it easy to find the latest End of Life (EOL) and End of Service Life (EOSL) information for your HPE hardware. HP, Compaq, StorageWorks, Smart Array, SupportPaq, and the HP and Compaq logo are. I can see the old arrays created in the storage trought the OS disk managment (windows 2000). 48 in active/passive configuration. . 0, W2K, W2K3) VCP (ESX2, Vi3, vSphere4, vSphere5, vSphere 6. . Allowing you to extend the support cycle and maximize the value of your hardware by saving 30 - 40% against that HPE contract. SSP is being used. I like a clean bowl & Never go with the zero. Learn more at the Official Hewlett Packard Enterprise Website. 101k 9 108 239. This notice is to explain the various stages of. HP split into two companies back in 2014. I've a replacement, but how can I savely switch to the non active redundant switch? 2. That is true - Brocade switches running 2. I´m connecting a MSA1000 with a Dell poweredge 2850. When the switch came online, it seemed to work; HP Systems Insight Manager showed that the switch was up and I could see it in the Switch. Public Sector; Service Providers; Small & Midsize Business; Financial; Health & Life Sciences; Manufacturing; Telecommunications; Media & Entertainment; All Solutions;Campus and Branch Networking; Data Center Networking; Small and Midsize Business NetworkingAll-flash and Hybrid Storage. HPE MSA 2050 SAN Storage: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. – jscott. I have configure MSA1000 with one logical drive and i configure all servers to have access to logical drive via Array Configuration Utility Selective Storage Presentation (SSP). HP-UX 11. I have three logical drives on a MSA1000. HP 411048-001 MSA1000 Smart Array Controller for Cluster w/256MB Cache. This process has multiple stages, which are described below. We have an MSA1000 which we want to use a tempory storage, but we have not spare fibre. Six Proliant Windows 2000 servers are connected to the MSA1000 using FC2101 HBA. My configuration: MSA1000. . Hi, My company bought over 1 HP MSA1000 from customer but we don't have the password to access the fabric switch web UI. so even this is at EOS limit. 34. 0a, MSA V4. The rest of the contoller configuration was still intact. MSA 1 and 6 servers are plugged on Ports 1-8 on both switches. From the web GUI, all devices can be seen accordingly except for the MSA1000 which does not have a product name/description to it. If I extend Logical Drive 2 then run the diskpart utility and the extend command will this work. The MSA is new to the windows environment and windows will be the only OS attached to it. 2K MidLine drives, 10K or 15K SAS drives. I then went to 5. Access Points and Controllers. 01. Hi, I have a MSA1000 starter kit with 6 Win2k3 servers, now we would like to have this MSA1000 replicate to a new MSA1000 on a remote DR site. 00 $525. I would like to migrate to A/A configuration with V7. Get the right storage, just when you need it. I'd give a reseat of the MSA1000-switches a shot, maybe that helps. After that I cannot get rid of this message in the ACU (screen capture attached). zip Has somebody a runnig linux configuration with active/passive MSA 1000 an Qlogic HBA? They will likely request information from you in order to look up your case details or product serial number. Hi, I have: 2 x MSA1000 (FW:4. It includes the MSA1000 itself along with the unique MSA SAN Switch 2/8 embedded option, two of the FCA2214 Host Bus Adapters for Windows, NetWare or Linux servers, SFPs and cabling. I have a MSA 1000 in active/standby configuration. Integrated with today’s most widely used hypervisors and operating systems, HPE MSA Gen6 enables you to power your workloads even as you work to lower costs. x). System 2 MSA2000 connected to 2 HP SAN 8/20q switches, there are no ISL links between to two switches. . 32B300. :( "Everything" has an IP address. We currently have an MSA1000 hooked to a Windows 2000 Server using a KGPSA-xx HBA via a Fabric Switch 6. The HPE MSA 2050 end of life and end of service can impact your data center operations, but you have options. HP StorageWorks Modular Smart Array 2012fc HP StorageWorks Modular Smart Array 2012i MSA2000 用3. 101k 9 108 239. Most lower end storage products have a 3 year sales run, with another 2-4 years of extended support, but this is really just part swaps not updates to keep relevant with the newer platforms. This problem exist in our production enviroment and in out lab, this issue looks like appear after the migration from 2003 to 2008 on the server that use this storage. Can i connect Bac. 48 firwmare on HP web. I have a new MSA1000 with an MSA30 running F/W Version 4. Hi all, i'm in the process of migrating our MSA1000 from active/passive to active/active. The storage is attached to HP Proliant DL380 G6 directly via fiber. Don’t fall under the impression that a hardware refresh is your only option when the HPE MSA 2050 SAN Storage EOSL comes to maturity – other HPE maintenance and support options. Find accurate end of life & end of service life dates for HPE MSA2060 hardware. 672 TB maximum including expansion, depending on model. 1 on Windows 2003 with MSA-1000 External SAN Storage and Networker 7. The Switch have been replaced, but we get issues with volumes returned and show by the secure path; We get also events on Windows OS's notified in the events logs concerning. . $325.